Urine flow test
Definition A urine flow test evaluates the speed of urination, or amount voided per second, and the total time of urination. Purpose A urine flow test is utilized to determine bladder function abnormalities, including a narrowed or obstructed urethra (the outflow passage from the bladder) and a weakened bladder muscle (detrusor). Description During a urine flow test, the patient urinates into a uroflowmeter, a funnel-shaped device that reads, measures, and computes the rate and amount of urine flow. The test takes approximately 10 minutes. Preparation The patient is prohibited from urinating at least two hours before the procedure. Normal results Average urine flow rates vary depending on age and gender. Abnormal results A urine flow test can indicate problems in bladder function, such as an obstruction, that will need further tests to diagnose. Key Terms - Detrusor muscle
- Bladder muscle.
- Urethra
- Passageway that carries urine from the bladder.
For Your Information Books - Pagana, Kathleen Deska. Mosby's Manual of Diagnostic and Laboratory Tests. St. Louis: Mosby, Inc., 1998.
- Walsh, Patrick C., et al., ed. Campbell's Urology. Philadelphia: W. B. Saunders Co., 1998.
Sources: Gale Encyclopedia of Medicine, Published December, 2002 by the Gale Group
The Essay Author is J. Ricker Polsdorfer MD.
|